Instrumentation, ind. & com. screen, unarmoured

Instrumentation  150/250 V

halogen free  -  flame retardant

   individual & common screen - unarmoured

operating temperature over 100 °C

(see page 6)

xiicimage

Design and construction

IEC 60092-376

Nominal voltage   Uo / U

150 / 250 V

Maximum voltage Umax

300 V

Maximum rated temperature

90 °C     according to   IEC 60092-360

Flame retardancy

IEC 60332-1-2              IEC 60332-3-22 Cat A

Halogen content & corrosivity

IEC 60754-1 / 2            IEC 60684-2

Smoke density

IEC 61034-1 / 2

Toxicity & smoke density

IMO RESOLUTION MSC 41(64)

UV resistance

UL 1581 § 1200

Ozone resistance

IEC 60092-360

Cold bend and Impact test (- 40° C)

CSA C 22.2 N° 0.3-01 & N° 38-05

 

Construction data

 

1  CONDUCTOR

plain or tinned annealed copper flexible Class 2 or                              

                                                Class 5   IEC 60092-376

2  INSULATION

XLPE HF compound                            IEC 60092-360

    CORES TWISTING

in pairs / triples

INDIVIDUAL SCREEN

Al/polyester tape (*) + tinned copper drain wire

COMMON  SCREEN

Al/polyester tape (*) + tinned copper drain wire

5  OUTER SHEATH

SHF1 or SHF2 compound                                IEC 60092-360

                                                       separator polyester tapes (*) where necessary                 

                     (*) tape overlapping ≥ 50 %

 

Cores identification

pair

black     light blue   

triple

black     light blue     brown

multi pairs/triples                             progressive numbers printed on insulation

 

Sheath colour

grey     (other colours on request)

 

Sheath marking

CCI    XI (ic)     150/250 V      n x (pair/triple) x sect  mm²       IEC 60092-376

IEC 60332-3-22 Cat A     meter marking      year      QA n°

·    Minimum Bending Radius:  4D (Overall Diameter) – see Generals section

  

 

APPROVED BY;
approvals
REQUEST INFORMATION:

This email address is being protected from spambots. You need JavaScript enabled to view it.

150 / 250 V

CONSTRUCTION

CONDUCTOR

DIAMETER

nominal

INSULATION

THICKNESS

nominal

OVERALL

DIAMETER

approx

WEIGHT

approx

n

pair

triple

 

[ mm² ]

[ mm ]

[ mm ]

[ mm ]

[ kg/km ]

2

x

2

x

0,75

1,1

0,6

10

110

4

x

2

x

0,75

1,1

0,6

12

170

7

x

2

x

0,75

1,1

0,6

15

250

10

x

2

x

0,75

1,1

0,6

18

350

14

x

2

x

0,75

1,1

0,6

21

460

19

x

2

x

0,75

1,1

0,6

24

600

24

x

2

x

0,75

1,1

0,6

27

740

30

x

2

x

0,75

1,1

0,6

29

900

 

2

x

3

x

0,75

1,1

0,6

12

180

4

x

3

x

0,75

1,1

0,6

14

230

7

x

3

x

0,75

1,1

0,6

17

370

10

x

3

x

0,75

1,1

0,6

21

510

14

x

3

x

0,75

1,1

0,6

24

630

19

x

3

x

0,75

1,1

0,6

27

850

 

CONSTRUCTION

CONDUCTOR

DIAMETER

nominal

INSULATION

THICKNESS

nominal

OVERALL

DIAMETER

approx

WEIGHT

approx

n

pair

triple

 

[ mm² ]

[ mm ]

[ mm ]

[ mm ]

[ kg/km ]

2

x

2

x

1,5

1,6

0,6

12

120

4

x

2

x

1,5

1,6

0,6

15

250

7

x

2

x

1,5

1,6

0,6

18

330

10

x

2

x

1,5

1,6

0,6

22

570

14

x

2

x

1,5

1,6

0,6

24,7

730

19

x

2

x

1,5

1,6

0,6

28

990

24

x

2

x

1,5

1,6

0,6

32

1.200

30

x

2

x

1,5

1,6

0,6

35

1.510

 

2

x

3

x

1,5

1,6

0,6

14

220

4

x

3

x

1,5

1,6

0,6

16

380

7

x

3

x

1,5

1,6

0,6

20

600

10

x

3

x

1,5

1,6

0,6

25

840

14

x

3

x

1,5

1,6

0,6

28

1.100

19

x

3

x

1,5

1,6

0,6

32

1.420