Instrumentation, individual screen, unarmoured
Instrumentation 150/250 V
halogen free - flame retardant
individual screen - unarmoured
operating temperature over 100 °C
(see page 6)
Design and construction | IEC 60092-376 |
Nominal voltage Uo / U | 150 / 250 V |
Maximum voltage Umax | 300 V |
aximum rated temperature | 90 °C according to IEC 60092-360 |
Flame retardancy | IEC 60332-1-2 IEC 60332-3-22 Cat A |
Halogen content & corrosivity | IEC 60754-1 / 2 IEC 60684-2 |
Smoke density | IEC 61034-1 / 2 |
Toxicity & smoke density | IMO RESOLUTION MSC 41(64) |
UV resistance | UL 1581 § 1200 |
Ozone resistance | IEC 60092-360 |
Cold bend and Impact test (- 40° C) | CSA C 22.2 N° 0.3-01 & N° 38-05 |
Construction | |
1 CONDUCTOR | plain or tinned annealed copper flexible Class 2 or Class 5 IEC 60092-376 |
2 INSULATION | XLPE HF compound IEC 60092-360 |
CORES TWISTING | in pairs / triples / quads |
3 INDIVIDUAL SCREEN | Al/polyester tape (*) + tinned copper drain wire |
4 OUTER SHEATH | SHF1 or SHF2 compound IEC 60092-360 |
separator polyester tapes (*) where necessary | |
(*) tape overlapping ≥ 50 % |
Cores identification | |
pair | black light blue |
triple | black light blue brown |
multi pairs/triples progressive numbers printed on insulation | |
Sheath colour | grey (other colours on request) |
Sheath marking | |
CCI XI(i) 150/250 V n x (pair/triple) x sect mm² IEC 60092-376 IEC 60332-3-22 Cat A meter marking year QA n° · Minimum Bending Radius: 4D (Overall Diameter) – see Generals section
|
APPROVED BY;
![approvals](../images/approvals.jpg)
REQUEST INFORMATION:
This email address is being protected from spambots. You need JavaScript enabled to view it.
CONSTRUCTION | CONDUCTOR DIAMETER (nominal) | INSULATION THICKNESS (nominal) | OVERALL DIAMETER (approx) | WEIGHT approx | ||||
n | pair/triple quad | [m m²] | [ mm ] | [ mm ] | [ mm ] | [ kg/km ] | ||
1 | x | 2 | x | 0,75 | 1,1 | 0,6 | 7 | 60 |
2 | x | 2 | x | 0,75 | 1,1 | 0,6 | 10 | 110 |
4 | x | 2 | x | 0,75 | 1,1 | 0,6 | 12 | 170 |
7 | x | 2 | x | 0,75 | 1,1 | 0,6 | 15 | 250 |
10 | x | 2 | x | 0,75 | 1,1 | 0,6 | 18 | 350 |
14 | x | 2 | x | 0,75 | 1,1 | 0,6 | 21 | 460 |
19 | x | 2 | x | 0,75 | 1,1 | 0,6 | 24 | 600 |
24 | x | 2 | x | 0,75 | 1,1 | 0,6 | 26 | 740 |
30 | x | 2 | x | 0,75 | 1,1 | 0,6 | 29 | 900 |
1 | x | 3 | x | 0,75 | 1,1 | 0,6 | 7 | 75 |
4 | x | 3 | x | 0,75 | 1,1 | 0,6 | 14 | 230 |
7 | x | 3 | x | 0,75 | 1,1 | 0,6 | 17 | 370 |
10 | x | 3 | x | 0,75 | 1,1 | 0,6 | 21 | 510 |
14 | x | 3 | x | 0,75 | 1,1 | 0,6 | 23 | 630 |
19 | x | 3 | x | 0,75 | 1,1 | 0,6 | 27 | 850 |
CONSTRUCTION | CONDUCTOR DIAMETER (nominal) | INSULATION THICKNESS (nominal) | OVERALL DIAMETER (approx) | WEIGHT approx | ||||
n | pair/triple quad | [m m²] | [ mm ] | [ mm ] | [ mm ] | [ kg/km ] | ||
1 | x | 2 | x | 1,5 | 1,6 | 0,6 | 8 | 85 |
2 | x | 2 | x | 1,5 | 1,6 | 0,6 | 12 | 160 |
4 | x | 2 | x | 1,5 | 1,6 | 0,6 | 15 | 280 |
7 | x | 2 | x | 1,5 | 1,6 | 0,6 | 18 | 430 |
10 | x | 2 | x | 1,5 | 1,6 | 0,6 | 22 | 570 |
14 | x | 2 | x | 1,5 | 1,6 | 0,6 | 25 | 730 |
19 | x | 2 | x | 1,5 | 1,6 | 0,6 | 28 | 990 |
24 | x | 2 | x | 1,5 | 1,6 | 0,6 | 32 | 1.200 |
30 | x | 2 | x | 1,5 | 1,6 | 0,6 | 35 | 1.510 |
1 | x | 3 | x | 1,5 | 1,6 | 0,6 | 8 | 110 |
4 | x | 3 | x | 1,5 | 1,6 | 0,6 | 16 | 380 |
7 | x | 3 | x | 1,5 | 1,6 | 0,6 | 20 | 600 |
10 | x | 3 | x | 1,5 | 1,6 | 0,6 | 25 | 840 |
14 | x | 3 | x | 1,5 | 1,6 | 0,6 | 28 | 1.100 |
19 | x | 3 | x | 1,5 | 1,6 | 0,6 | 32 | 1.500 |