Instrumentation, individual screen, unarmoured

Instrumentation 150/250 V

halogen free - flame retardant

   individual screen - unarmoured

operating temperature over 100 °C

(see page 6)

xi(i) Cableservice Marine Cables

Design and construction

IEC 60092-376

Nominal voltage Uo / U

150 / 250 V

Maximum voltage Umax

300 V

aximum rated temperature

90 °C        according to       IEC 60092-360

Flame retardancy

IEC 60332-1-2                       IEC 60332-3-22 Cat A

Halogen content & corrosivity

IEC 60754-1 / 2                     IEC 60684-2

Smoke density

IEC 61034-1 / 2

Toxicity & smoke density

IMO RESOLUTION MSC 41(64)

UV resistance

UL 1581 § 1200

Ozone resistance

IEC 60092-360

Cold bend and Impact test (- 40° C)

CSA C 22.2 N° 0.3-01 & N° 38-05

 

Construction

 

1 CONDUCTOR

plain or tinned annealed copper flexible Class 2 or                                

                                             Class 5   IEC 60092-376

2 INSULATION

XLPE HF compound                     IEC 60092-360

   CORES TWISTING

in pairs / triples / quads

3 INDIVIDUAL SCREEN

Al/polyester tape (*) + tinned copper drain wire

4 OUTER SHEATH

SHF1 or SHF2 compound             IEC 60092-360

                                                               separator polyester tapes (*) where necessary                  

                          (*) tape overlapping ≥ 50 %

 

Cores identification

pair

black   light blue  

triple

black   light blue brown

multi pairs/triples                                progressive numbers printed on insulation

Sheath colour

grey     (other colours on request)

Sheath marking

CCI   XI(i)      150/250 V    n x (pair/triple) x sect mm²  IEC 60092-376

IEC 60332-3-22 Cat A   meter marking   year   QA n°

· Minimum Bending Radius: 4D (Overall Diameter) – see Generals section

   

 


 

APPROVED BY;
approvals
REQUEST INFORMATION:

This email address is being protected from spambots. You need JavaScript enabled to view it.

150 / 250 V

CONSTRUCTION

CONDUCTOR

DIAMETER

(nominal)

INSULATION

THICKNESS

(nominal)

OVERALL

DIAMETER

(approx)

WEIGHT

approx

n

pair/triple

quad

[m m²]

[ mm ]

[ mm ]

[ mm ]

[ kg/km ]

1

x

2

x

0,75

1,1

0,6

7

60

2

x

2

x

0,75

1,1

0,6

10

110

4

x

2

x

0,75

1,1

0,6

12

170

7

x

2

x

0,75

1,1

0,6

15

250

10

x

2

x

0,75

1,1

0,6

18

350

14

x

2

x

0,75

1,1

0,6

21

460

19

x

2

x

0,75

1,1

0,6

24

600

24

x

2

x

0,75

1,1

0,6

26

740

30

x

2

x

0,75

1,1

0,6

29

900

 

1

x

3

x

0,75

1,1

0,6

7

75

4

x

3

x

0,75

1,1

0,6

14

230

7

x

3

x

0,75

1,1

0,6

17

370

10

x

3

x

0,75

1,1

0,6

21

510

14

x

3

x

0,75

1,1

0,6

23

630

19

x

3

x

0,75

1,1

0,6

27

850

 

CONSTRUCTION

CONDUCTOR

DIAMETER

(nominal)

INSULATION

THICKNESS

(nominal)

OVERALL

DIAMETER

(approx)

WEIGHT

approx

n

pair/triple

quad

[m m²]

[ mm ]

[ mm ]

[ mm ]

[ kg/km ]

1

x

2

x

1,5

1,6

0,6

8

85

2

x

2

x

1,5

1,6

0,6

12

160

4

x

2

x

1,5

1,6

0,6

15

280

7

x

2

x

1,5

1,6

0,6

18

430

10

x

2

x

1,5

1,6

0,6

22

570

14

x

2

x

1,5

1,6

0,6

25

730

19

x

2

x

1,5

1,6

0,6

28

990

24

x

2

x

1,5

1,6

0,6

32

1.200

30

x

2

x

1,5

1,6

0,6

35

1.510

 

1

x

3

x

1,5

1,6

0,6

8

110

4

x

3

x

1,5

1,6

0,6

16

380

7

x

3

x

1,5

1,6

0,6

20

600

10

x

3

x

1,5

1,6

0,6

25

840

14

x

3

x

1,5

1,6

0,6

28

1.100

19

x

3

x

1,5

1,6

0,6

32

1.500

 