Instrumentation, common screen, unarmoured

Instrumentation  150/250 V

halogen free  -  flame retardant

   common screen - armoured

operating temperature over 100 °C

(see page 6)

Design and construction

IEC 60092-376

Nominal voltage   Uo / U

150 / 250 V

Maximum voltage Umax

 300 V

Maximum rated temperature

90 °C     according to   IEC 60092-360

Flame retardancy

IEC 60332-1-2                IEC 60332-3-22 Cat A

 Halogen content & corrosivity

IEC 60754-1 / 2            IEC 60684-2

Smoke density

IEC 61034-1 / 2

Toxicity & smoke density

IMO RESOLUTION MSC 41(64)

UV resistance

UL 1581 § 1200

Ozone resistance

IEC 60092.360

Cold bend and Impact test (- 40° C)

CSA C 22.2 N° 0.3-01 & N° 38-05

 

Construction

 

1  CONDUCTOR

  plain or tinned annealed copper flexible Class 2 or                               

                                           Class 5   IEC60092-376

2  INSULATION

  XLPE HF compound                      IEC 60092-360

    CORES TWISTING

  in pairs / triples

COMMON SCREEN

  Al/polyester tape (*) + tinned copper drain wire

4  ARMOUR

  plain or tinned copper or galvanized steel wire braid

5  OUTER SHEATH

  SHF1 or SHF2 compound             IEC 60092-360

                                                                       separator polyester tapes (*) where necessary 

                                                                       (*) tape overlapping ≥ 50 %

 

 Cores identification

 pair

 black    light blue   

 triple

 black    light blue     brown

 multi pairs/triples                                   progressive numbers printed on insulation

 

Sheath colour

 grey    (other colours on request)

Sheath marking

CCI   XAI(c)     150/250 V        n x (pair/triple) x sect   mm²           IEC 60092-376

IEC 60332-3-22 Cat A    meter marking     year    QA n°

 

  • Minimum Bending Radius:  4D (Overall Diameter) – see Generals section    

 

APPROVED BY;
approvals
REQUEST INFORMATION:

This email address is being protected from spambots. You need JavaScript enabled to view it.

150 / 250 V

CONSTRUCTION

CONDUCTOR

DIAMETER

nominal

INSULATION

 THICKNESS

nominal

DIAMETER

UNDER ARMOUR

nominal

OVERALL

 DIAMETER

approx

WEIGHT

approx

n

pair

triple

[m m²]

[ mm ]

[ mm ]

[ mm ]

[ mm ]

[ kg/km ]

2

x

2

x

0,75

1,1

0,6

5,2

11

220

4

x

2

x

0,75

1,1

0,6

9,2

13

280

7

x

2

x

0,75

1,1

0,6

11,8

16

320

10

x

2

x

0,75

1,1

0,6

14,8

19

470

14

x

2

x

0,75

1,1

0,6

16,9

22

570

19

x

2

x

0,75

1,1

0,6

19,7

25

730

24

x

2

x

0,75

1,1

0,6

22,3

27

870

30

x

2

x

0,75

1,1

0,6

24,2

30

1.050

 

2

x

3

x

0,75

1,1

0,6

9,2

12

260

4

x

3

x

0,75

1,1

0,6

10,8

15

360

7

x

3

x

0,75

1,1

0,6

13,9

18

420

10

x

3

x

0,75

1,1

0,6

17,2

22

600

14

x

3

x

0,75

1,1

0,6

19,3

25

790

19

x

3

x

0,75

1,1

0,6

22,7

28

1.000

 

2

x

2

x

1,5

1,6

0,6

6,7

10

250

4

x

2

x

1,5

1,6

0,6

11,6

16

450

7

x

2

x

1,5

1,6

0,6

14,4

19

450

10

x

2

x

1,5

1,6

0,6

18,1

23

500

14

x

2

x

1,5

1,6

0,6

20,5

25

700

19

x

2

x

1,5

1,6

0,6

23,9

29

1.020

24

x

2

x

1,5

1,6

0,6

268

32

1.330

30

x

2

x

1,5

1,6

0,6

30,0

36

1.710

 

2

x

3

x

1,5

1,6

0,6

10,9

14

390

4

x

3

x

1,5

1,6

0,6

13,0

17

540

7

x

3

x

1,5

1,6

0,6

16,9

21

760

10

x

3

x

1,5

1,6

0,6

21,1

26

1.050

14

x

3

x

1,5

1,6

0,6

22,6

29

1.230

19

x

3

x

1,5

1,6

0,6

27,5

34

1.580